T6200 Industrial Online pH/DO Dual-channel Transmitter

Short Description:

Industrial on-line DO/DO transmitter is an on-line water quality dual channel monitoring and control instrument with microprocessor.The DO value and temperature value of aqueous solution were continuously monitored and controlled.The instrument is equipped with different types of sensors. Widely used in power plants, petrochemical industry, metallurgical electronics, mining, paper industry, biological fermentation engineering, medicine, food and beverage, environmental protection water treatment, aquaculture, modern agricultural planting and other industries.


  • Measurement range: DO: 0-20mg/L
  • Resolution: 0.01mg/L; 0.1%
  • Basic error: ±1%F.S
  • Temperature: -10~150.0℃
  • Current Output: 4~20mA,20~4mA,0~20mA(load resistance<750Ω)
  • Communication output: RS485 MODBUS RTU
  • Relay control contacts: 5A 240VAC,5A 28VDC or 120VAC
  • Working temperature: -10~60℃
  • IP rate: IP65
  • Instrument Dimensions: 144×144×118mm

Product Detail

Product Tags

T6200 Industrial Online pH/DO Dual-channel Transmitter

Online DO&DO Dual Channel Transmitter
6000-A
6000-B
Function
Industrial on-line DO/DO transmitter is an on-line water quality dual channel monitoring and control instrument with microprocessor.The DO value and temperature value of aqueous solution were continuously monitored and controlled.
Typical Use
The instrument is equipped with different types of sensors. Widely used in power plants, petrochemical industry, metallurgical electronics, mining, paper industry, biological fermentation engineering, medicine, food and beverage, environmental protection water treatment, aquaculture, modern agricultural planting and other industries.
Mains Supply
85~265VAC±10%,50±1Hz, power ≤3W;
9~36VDC, power consumption≤3W;
Measuring Range
Dissolved Oxygen:0-20mg/L;
Tempreature:-10~150.0℃;

T6200 Industrial Online pH/DO Dual-channel Transmitter

Industrial Online Dual-channel Transmitter

Measurement mode

Industrial Online Dual-channel Transmitter

Calibration mode

Industrial Online Dual-channel Transmitter

Trend chart

Industrial Online Dual-channel Transmitter

Setting mode

Features

1. Large display, standard 485 communication, with online and offline alarm, 144*144*118mm meter size, 138*138mm hole size, 4.3 inch large screen display.

2. Intelligent menu operation

3. Multiple automatic calibration

4. Differential signal measurement mode, stable and reliable

5. Manual and automatic temperature compensation 6. Three relay control switches

7. 4-20mA & RS485,Multiple output modes

8. Multi parameter display simultaneously shows – DO/ DO, Temp, current,etc.

9. Password protection to prevent misoperation by non- staff.

10. The matching installation accessories make the

installation of the controller in complex working conditions more stable and reliable.

11. High & low alarm and hysteresis control. Various alarm outputs. In addition to the standard two-way normally  open contact design, the option of normally closed contacts is also added to make the dosing control more targeted.

12. The 3-terminal waterproof sealing joint effectively prevents water vapor from entering, and isolates the input, output and power supply, and the stability is greatly improved. High resilience silicone keys, easy to use, can use combination keys, easier to operate.

13.The outer shell is coated with protective metal paint, and safety capacitors are added to the power board, which improves the strong magnetic

anti-interference ability of industrial field equipment. The shell is made of  PPS material for more corrosion resistance.

The sealed  and waterproof back cover can effectively prevent water vapor from entering, dustproof, waterproof, and corrosion-proof, which greatly improves the protection capability of the whole machine.

Electrical connections
Electrical connection The connection between the instrument and the sensor: the power supply, output signal, relay alarm contact and the connection between the sensor and the instrument are all inside the instrument. The length of the lead wire for the fixed electrode is usually 5-10 meters, and the corresponding label or color on the sensor Insert the wire into the corresponding terminal inside the instrument and tighten it.
Instrument installation method
11
Technical specifications
Measuring range DO: 0-20mg/L
Unit mg/L
Resolution 0.01mg/L
Basic error ±0.1mg/L
Temperature -10~150.0(  Depend on the Sensor)
Temp. resolution 0.1℃
Temp. accuracy ±0.3℃
Temp. compensation 0~150.0℃
Temp. compensation Manual or automatic
Stability pH:≤0.01pH/24h;
Current outputs Two 4~20mA,20~4mA,0~20mA
Signal output RS485 MODBUS RTU
Other functions Data record &Curve display
Three relay control contacts 5A 250VAC,5A 30VDC
Optional power supply 85~265VAC,9~36VDC,power consumption ≤3W
Working conditions No strong magnetic field interference around except the geomagnetic field.
Working temperature -10~60℃
Relative humidity ≤90%
Waterproof rating IP65
Weight 0.8kg
Dimensions 144×144×118mm
Installation opening size 138×138mm
Installation methods Panel & wall mounted or pipeline

CS4760D Dissolved Oxygen Sensor

Digital Dissolved Oxygen Sensor
Introduction:
Dissolved oxygen sensor uses fluorescence measurement of dissolved oxygen, blue light emitted by the phosphor layer, a fluorescent substance is excited to emit red light, and the fluorescent substance and the concentration of oxygen is inversely proportional to the time back to the ground state. The method uses a measurement of dissolved oxygen, no oxygen consumption measurement, the data is stable, reliable performance, there is no interference, installation and calibration simple. Widely used in sewage treatment plants each process, water plants, surface water, industrial process water production and wastewater treatment, aquaculture and other industries on-line monitoring of DO.
Features:
1. The sensor uses a new type of oxygen-sensitive film with good reproducibility and stability. Breakthrough fluorescence techniques, requires virtually no maintenance.
2. Maintain prompt the user can customize the prompt message is automatically triggered.
3. Hard, fully enclosed design, improved durability.
4. Use simple, reliable, and interface instructions can reduce operational errors.
5. Set a visual warning system to provide important alarm functions.
6. Sensor convenient on-site installation, plug and play
Technical specifications:
Model No. CS4760D
Power/Output 9~36VDC/RS485 MODBUS RTU
Measuring Mode Fluorescence method
Housing Material POM+316LStainless steel
Waterproof Rating IP68
Measuring Range 0-20mg/L
Accuracy ±1%F.S
Pressure Range ≤0.3Mpa
Temperature Compensation NTC10K
Temperature Range 0-50℃
Calibration Anaerobic Water Calibration and Air Calibration
Connection Method 4 core or 6 core cable
Cable Length Standard 10m cable, can be extended
Installation Thread G3/4’’
 

Application

General application, river, lake,drink water, environment

protection ,etc