CS1737 Plastic Housing pH Sensor

Short Description:

Designed for Hydrofluoric acid environment.
HF concentration>1000ppm
The electrode is made of ultra-bottom impedance-sensitive glass film, and it also has the characteristics of fast response, accurate measurement, good stability, and not easy to hydrolyze in the case of hydrofluoric acid environment media. The reference electrode system is a non-porous, solid, non-exchange reference system. Completely avoid various problems caused by the exchange and blockage of the liquid junction,such as the reference electrode is easy to be polluted, reference vulcanization poisoning, reference loss and other problems.


Product Detail

Product Tags

CS1737 pH Sensor

Designed for Hydrofluoric acid environment.

HF concentration>1000ppm

The electrode is made of ultra-bottom impedance-sensitive glass film, and it also has the characteristics of fast response, accurate measurement, good stability, and not easy to hydrolyze in the case of hydrofluoric acid environment media. The reference electrode system is a non-porous, solid, non-exchange reference system. Completely avoid various problems caused by the exchange and blockage of the liquid junction,such as the reference electrode is easy to be polluted, reference vulcanization poisoning, reference loss and other problems.

Double salt bridge design, double layer seepage interface, resistant to medium reverse seepage

The ceramic pore parameter electrode oozes out of the interface and is not easy to be blocked, which is suitable for monitoring of hydrofluoric acid environmental media.

High-strength glass bulb design, the glass appearance is stronger.

The electrode adopts low noise cable, the signal output is farther and more stable

Large sensing bulbs increase the ability to sense hydrogen ions, and perform well in hydrofluoric acid environment media.

Model No.

CS1737

Measure material

Antimony

pH zero point

7.00±0.25pH

Reference system

SNEX Ag/AgCl/KCl

Electrolyte solution

3.3M KCl

Membrane resistance

<500MΩ

Housing material

PP

Liquid junction

SNEX

Waterproof grade

IP68

Measurement range

2-12pH

Accuracy

±0.05pH

Pressure resistance

≤0.6Mpa

Temperature compensation

NTC10K,PT100,PT1000 (Optional)

Temperature range

0-80℃

Calibration

Sample calibration, standard liquid calibration

Double Junction

Yes

Cable length

Standard 5m cable, can be extended to 100m

Installation thread

NPT3/4”

Application

Hydrofluoric acid environment, HF>1000PPM 

 


  • Previous:
  • Next:

  • Write your message here and send it to us