Digital Ion Selective Sensor

  • Water Online Digital RS485 Chloride Ion Selective Sensor for Water Monitoring CS6711AD

    Water Online Digital RS485 Chloride Ion Selective Sensor for Water Monitoring CS6711AD

    CS6711AD digital chloride ion sensor uses a solid membrane ion selective electrode for testing fluoride ions floating in water, which is fast, simple, accurate and economical.The design adopts the principle of single-chip solid ion selective electrode, with high measurement accuracy. Double salt bridge design, longer service life.The patented chloride ion probe, with an internal reference fluid at a pressure of at least 100KPa (1Bar), seeps extremely slowly from the microporous salt bridge. Such a reference system is very stable and the electrode life is longer than the ordinary.
  • Digital Fluoride Ion Online ISE Probe for Wastewater Treatment Sensor CS6710AD

    Digital Fluoride Ion Online ISE Probe for Wastewater Treatment Sensor CS6710AD

    CS6710AD digital fluoride ion sensor uses a solid membrane ion selective electrode for testing fluoride ions floating in water, which is fast, simple, accurate and economical. The design adopts the principle of single-chip solid ion selective electrode, with high measurement accuracy. Double salt bridge design, longer service life.The patented fluoride ion probe, with an internal reference fluid at a pressure of at least 100KPa (1Bar), seeps extremely slowly from the microporous salt bridge. Such a reference system is very stable and the electrode life is longer than the ordinary.
  • Industrial Online Nitrate Nitrogen Sensor NO3-N Chloride Ion Probe Compensation Meter

    Industrial Online Nitrate Nitrogen Sensor NO3-N Chloride Ion Probe Compensation Meter

    On-line nitrite nitrogen sensor, no reagents required, green and non-polluting, can be monitored online in real time. Integrated nitrate, chloride (optional), and reference electrodes automatically compensate for chloride (optional), and temperature in water. It can be directly put into installation, which is more economical, environmentally friendly and convenient than traditional ammonia nitrogen analyzer. It adopts RS485 or 4-20mA output and supports Modbus for easy integration.
  • Online Digital Nitrate ion Sensor Water Tester Probe SOutput Signal ensor

    Online Digital Nitrate ion Sensor Water Tester Probe SOutput Signal ensor

    The electrochemistry sensor uses membrane potential to determine the activity or concentration of ions in solution. When it is in contact with a solution containing the measured ion, a membrane potential directly related to the ion activity is generated at the phase interface of its sensitive film and solution.The parameters that characterize the basic properties of ion-selective electrodes are selectivity,dynamic range of measurements, response speed, accuracy, stability, and lifetime.
  • CS6800D High Accuracy Online Nitrate Ion Selective Sensor RS485 NO3 Nitrate Nitrogen Sensor

    CS6800D High Accuracy Online Nitrate Ion Selective Sensor RS485 NO3 Nitrate Nitrogen Sensor

    NO3 absorbs ultraviolet light at 210 nm. When the probe works, the water sample flows through the slit. When the light emitted by the light source in the probe passes through the slit, part of the light is absorbed by the sample flowing in the slit. The other light passes through the sample and reaches the detector on the other side of the probe to calculate the nitrate concentration.
  • Hardness Calcium Ion Selective Electrode CS6718SD

    Hardness Calcium Ion Selective Electrode CS6718SD

    Ion selective electrode is a kind of electrochemical sensor that uses membrane potential to measure the activity or concentration of ions in the solution. When it comes into contact with the solution containing the ions which are to be measured, it will generate contact with the sensor at the interface between its sensitive
    membrane and the solution. Ion activity is directly related to membrane potential. Ion selective electrodes are also called membrane electrodes. This type of electrode has a special electrode membrane that selectively responds to specific ions.
  • Digital sensor Fluoride Chloride Chloride Potassium Nitrate ion for wastewater sensor CS6710AD

    Digital sensor Fluoride Chloride Chloride Potassium Nitrate ion for wastewater sensor CS6710AD

    CS6710AD digital fluoride ion sensor uses a solid membrane ion selective electrode for testing fluoride ions floating in
    water, which is fast, simple, accurate and economical.
    The design adopts the principle of single-chip solid ion selective electrode, with high measurement accuracy. Double salt
    bridge design, longer service life.
    The patented fluoride ion probe, with an internal reference fluid at a pressure of at least 100KPa (1Bar), seeps extremely
    slowly from the microporous salt bridge. Such a reference system is very stable and the electrode life is longer than the ordinary.
  • Digital ISE Sensor Series CS6712SD

    Digital ISE Sensor Series CS6712SD

    The CS6712SD potassium ion selective electrode is an effective method to measure the potassium ion content in the sample. Potassium ion selective electrodes are also often used in online instruments, such as industrial online potassium ion content monitoring. , Potassium ion selective electrode has the advantages of simple measurement, fast and accurate response. It can be used with PH meter, ion meter and online potassium ion analyzer, and also used in electrolyte analyzer, and ion selective electrode detector of flow injection analyzer.
  • Digital RS485 Nitrate Ion Selective Sensor NO3- Electrode Probe 4~20mA Output CS6720SD

    Digital RS485 Nitrate Ion Selective Sensor NO3- Electrode Probe 4~20mA Output CS6720SD

    Ion selective electrode is a kind of electrochemical sensor that uses membrane potential to measure the activity or concentration of ions in the solution. When it comes into contact with the solution containing the ions which are to be measured, it will generate contact with the sensor at the interface between its sensitive
    membrane and the solution. Ion activity is directly related to membrane potential. Ion selective electrodes are also called membrane electrodes. This type of electrode has a special electrode membrane that selectively responds to specific ions.
  • Digital Ammonium Ion Selective Sensor NH4 Electrode RS485 CS6714SD

    Digital Ammonium Ion Selective Sensor NH4 Electrode RS485 CS6714SD

    An electrochemical sensor for determining the activity or concentration of ions in a solution using a membrane potential. When it is in contact with a solution containing the measured ion, a membrane potential directly related to the activity of the ion is generated at the phase interface between its sensitive membrane and the solution. ion selective electrodes are one-half batteries (except gas-sensitive electrodes) that must be composed of complete electrochemical cells with appropriate reference electrodes.
  • Digital Ammonium Nitrogen Ion Selective Sensor NH3+ pH Sensor CS6714AD

    Digital Ammonium Nitrogen Ion Selective Sensor NH3+ pH Sensor CS6714AD

    An electrochemical sensor for determining the activity or concentration of ions in a solution using a membrane potential. When it is in contact with a solution containing the measured ion, a membrane potential directly related to the activity of the ion is generated at the phase interface between its sensitive membrane and the solution. ion selective electrodes are one-half batteries (except gas-sensitive electrodes) that must be composed of complete electrochemical cells with appropriate reference electrodes.
  • Online Digital NH3-N Potassium Ion Compensation Ammonia Nitrogen Sensor RS485

    Online Digital NH3-N Potassium Ion Compensation Ammonia Nitrogen Sensor RS485

    On-line ammonia nitrogen sensor, no reagents required, green and non-polluting, can be monitored online in real time. Integrated ammonium, potassium (optional), pH and reference electrodes automatically compensate for potassium (optional), pH and temperature in water. It can be directly put into installation,which is more economical, environmentally friendly and convenient than traditional ammonia nitrogen analyzer. The sensor has a self-cleaning brush
    that prevents microbial adhesion, resulting in longer maintenance intervals and excellent reliability. It adopts RS485 output and supports Modbus for easy integration.