CS7850D Digital Suspended Solids (Sludge concentration) Sensor

Short Description:

The principle of the sludge concentration sensor is based on the combined infrared absorption and scattered light method. The ISO7027 method can be used to continuously and accurately determine the sludge concentration. According to ISO7027 infrared double-scattering light technology is not affected by chromaticity to determine the sludge concentration value. The self-cleaning function can be selected according to the use environment. Stable data, reliable performance; built-in self-diagnosis function to ensure accurate data; simple installation and calibration.


Product Detail

Product Tags

Suspended Solids

Introduction:

The principle of the sludge concentration sensor is based on the combined infrared absorption and scattered light method. The ISO7027 method can be used to continuously and accurately determine the sludge concentration. According to ISO7027 infrared double-scattering light technology is not affected by chromaticity to determine the sludge concentration value. The self-cleaning function can be selected according to the use environment. Stable data, reliable performance; built-in self-diagnosis function to ensure accurate data; simple installation and calibration.

The electrode body is made of 316L stainless steel, which is corrosion-resistant and more durable. The seawater version can be plated with titanium, which also performs well under strong corrosion. IP68 waterproof design, can be used for input measurement.

0-200mg/L, 0-5000mg/L, 0-50000mg/L, a variety of measuring ranges are available, suitable for different working conditions, the measurement accuracy is less than ±5% of the measured value. 

The sludge concentration meter is an online analytical instrument designed to measure the concentration of suspended solids in the treatment of municipal sewage or industrial wastewater. Whether evaluating activated sludge and the entire biological treatment process, analyzing wastewater discharged after purification treatment, or detecting sludge concentration at different stages, the sludge concentration meter can give continuous and accurate measurement results.

Typical application:

Suspended Solids (Sludge concentration) monitoring of water from waterworks, water quality monitoring of municipal pipeline network; industrial process water quality monitoring, circulating cooling water, activated carbon filter effluent, membrane filtration effluent, etc.

Technical parameters:

Model No.

CS7850D/CS7851D/CS7860D

Power/Outlet

9~36VDC/RS485 MODBUS RTU

Measurement mode

90°IR scattered light method

Dimensions

Diameter 50mm*Length 223mm

Housing material

POM+316 Stainless steel

Waterproof rating

IP68

Measurement range

2-200 mg/L/5000mg/L/50000mg/L

Measurement accuracy

±5% or 0.5mg/L,whichever is greater

Pressure resistance

≤0.3Mpa

Measuring temperature

0-45℃

Calibration

Standard liquid calibration, water sample calibration

Cable length

10m or customize

Thread

G3/4

Weight

1.5kg

Application

General applications, rivers, lakes, environmental protection, etc.