Home
About us
Company profile
Company certificate
Products
laboratory series
Pen Type
Portable
Laboratory
Multi-parameter Monitor Series
Digital Transmitter and Sensors Series
Digital pH Sensor
Digital ORP Sensor
Digital Ion Selective Sensor
Digital Conductivity Sensor
Digital Dissolved Oxygen Sensor
Digital Residual Chlorine Sensor
Digital Suspended Solids(Sludge Concentration) Sensor
Digital Turbidity Sensor
Digital Chlorophyll Analyzer
Digital Blue-Green Algae Analyzer
Digital COD Sensor
pH/ORP/ION Series
pH/ORP Transmitter
Ion Transmitter/Ion Sensor
Conductivity/TDS/Resistivity/Salinity Series
Conductivity Transmitter
Acid-base salt concentration Transmitter
Dissolved Oxygen Series
Fluorescent Dissolved Oxygen Transmitter
Polarography Dissolved Oxygen Transmitter
Micro Dissolved Oxygen Transmitter
Suspended Solids(Sludge Concentration)/Turbidity Series
Suspended Solids(Sludge Concentration) Transmitter
Turbidity Transmitter/Turbidity Sensor
Disinfectant water monitoring series
Residual Chlorine Transmitter
Chlorine Dioxide Transmitter
Dissolved Ozone Transmitter
Ultrasonic Series
Liquid Level Meter
Sludge Interface Meter
Application
Field Installation
News
Support
After Sales Service
Download
CE Certificate
Operation manual
Conductivity&TDS& Resistivity& Salinity
Dissolved Oxygen Series
Ion Concentrations Series
PH&ORP Series
Residual Chlorine& Chlorine Dioxide& Dissolved Ozone
Turbidity&Suspended Solids Series
FAQs
Contact us
English
ALL PRODUCT CATEGORIES
Digital Transmitter and Sensors Series
Online Digital NH3-N Potassium Ion Compensation Ammonia Nitrogen Sensor RS485
On-line ammonia nitrogen sensor, no reagents required, green and non-polluting, can be monitored online in real time. Integrated ammonium, potassium (optional), pH and reference electrodes automatically compensate for potassium (optional), pH and temperature in water. It can be directly put into installation,which is more economical, environmentally friendly and convenient than traditional ammonia nitrogen analyzer. The sensor has a self-cleaning brush
that prevents microbial adhesion, resulting in longer maintenance intervals and excellent reliability. It adopts RS485 output and supports Modbus for easy integration.
inquiry
detail
CE Digital Salinity/Ec/Conductivity Meter Ultra Pure Water Sensor CS3743D
For continuous monitoring and control of conductivity / TDS and temperature values of aqueous solutions. Widely used in power plants, petrochemical, metallurgy, paper industry, environmental water treatmen and other fields. For example, monitoring and control of raw water and water quality of water production equipment such as recharge water, saturated water, condensate water and furnace water, ion exchange, reverse osmosis EDL,seawater distillation
inquiry
detail
pH/ORP Sensor Digital Glass pH ORP Probe Sensor Electrode CS2543D
Double salt bridge design, double layer seepage interface, resistant to medium reverse seepage. The ceramic pore parameter electrode oozes out of the interface and is not easy to be blocked, which is suitable for monitoring of common water quality environmental media.
inquiry
detail
CS1778D Digital pH Sensor
Designed for flue gas desulfurization environment.
Easy to connect to PLC, DCS, industrial control computers, general purpose controllers, paperless recording instruments or touch screens and other third party devices.
inquiry
detail
Chlorophyll Online Analyzer T6400
Industrial Chlorophyll Online Analyzer is an online water quality monitor and control instrument with microprocessor. It is widely used in power plants, petrochemical industry, metallurgical electronics, mining, paper industry, food and beverage industry, environmental protection water treatment, aquaculture and other industries. The Chlorophyll value and temperature value of water solution are continuously monitored and controlled.
inquiry
detail
CS3742D Conductivity Sensor
Designed for Pure, Boiler Feed water, Power Plant, Condensate Water.
Easy to connect to PLC, DCS, industrial control computers, general purpose controllers, paperless recording instruments or touch screens and other third party devices.
inquiry
detail
Digital Turbidity Sensor with Automatic Cleaning
The principle of the turbidity sensor is based on the combined infrared absorption and scattered light method. The ISO7027 method can be used to continuously and accurately determine the turbidity value. According to ISO7027 infrared double-scattering light technology is not affected by chromaticity to determine the sludge concentration value. The self-cleaning function can be selected according to the use environment. Stable data, reliable performance; built-in self-diagnosis function to ensure accurate data; simple installation and calibration.
inquiry
detail
Digital Turbidity Sensor with Automatic Cleaning
The principle of the turbidity sensor is based on the combined infrared absorption and scattered light method. The ISO7027 method can be used to continuously and accurately determine the turbidity value. According to ISO7027 infrared double-scattering light technology is not affected by chromaticity to determine the sludge concentration value. The self-cleaning function can be selected according to the use environment. Stable data, reliable performance; built-in self-diagnosis function to ensure accurate data; simple installation and calibration.
inquiry
detail
CS7800D Online Turbidity Sensor
The principle of the turbidity sensor is based on the combined infrared absorption and scattered light method. The ISO7027 method can be used to continuously and accurately determine the turbidity value. According to ISO7027 infrared double-scattering light technology is not affected by chromaticity to determine the sludge concentration value. The self-cleaning function can be selected according to the use environment. Stable data, reliable performance; built-in self-diagnosis function to ensure accurate data; simple installation and calibration.
inquiry
detail
CS7920D Online Flow-through Turbidity Sensor
The principle of the turbidity sensor is based on the combined infrared absorption and scattered light method. The ISO7027 method can be used to continuously and accurately determine the turbidity value. According to ISO7027 infrared double-scattering light technology is not affected by chromaticity to determine the sludge concentration value. The self-cleaning function can be selected according to the use environment. Stable data, reliable performance; built-in self-diagnosis function to ensure accurate data; simple installation and calibration.
inquiry
detail
Online Immersion Type Turbidity Sensor
The principle of the turbidity sensor is based on the combined infrared absorption and scattered light method. The ISO7027 method can be used to continuously and accurately determine the turbidity value. According to ISO7027 infrared double-scattering light technology is not affected by chromaticity to determine the sludge concentration value. The self-cleaning function can be selected according to the use environment. Stable data, reliable performance; built-in self-diagnosis function to ensure accurate data; simple installation and calibration.
inquiry
detail
Digital Suspended Solids (Sludge concentration) Sensor
The principle of the sludge concentration sensor is based on the combined infrared absorption and scattered light method. The ISO7027 method can be used to continuously and accurately determine the sludge concentration. According to ISO7027 infrared double-scattering light technology is not affected by chromaticity to determine the sludge concentration value. The self-cleaning function can be selected according to the use environment. Stable data, reliable performance; built-in self-diagnosis function to ensure accurate data; simple installation and calibration.
inquiry
detail
<<
< Previous
7
8
9
10
11
12
Next >
>>
Page 10 / 12
Hit enter to search or ESC to close