Digital Transmitter and Sensors Series

  • CS6602HD Digital Chemical Oxygen Demand Electrode Probe COD Sensor RS485

    CS6602HD Digital Chemical Oxygen Demand Electrode Probe COD Sensor RS485

    COD sensor is a UV absorption COD sensor, combined with a lot of application experience, based on the original basis of a number of upgrades, not only the size is smaller, but also the original separate cleaning brush to do one, so that the installation is more convenient, with higher reliability.It does not need reagent, no pollution, more economic and environmental protection.On-line uninterrupted water quality monitoring.Automatic compensation for turbidity interference, with automatic cleaning device, even if long-term monitoring still has excellent stability
  • CS6800D High Accuracy Online Nitrate Ion Selective Sensor RS485 NO3 Nitrate Nitrogen Sensor

    CS6800D High Accuracy Online Nitrate Ion Selective Sensor RS485 NO3 Nitrate Nitrogen Sensor

    NO3 absorbs ultraviolet light at 210 nm. When the probe works, the water sample flows through the slit. When the light emitted by the light source in the probe passes through the slit, part of the light is absorbed by the sample flowing in the slit. The other light passes through the sample and reaches the detector on the other side of the probe to calculate the nitrate concentration.
  • Hardness Calcium Ion Selective Electrode CS6718SD

    Hardness Calcium Ion Selective Electrode CS6718SD

    Ion selective electrode is a kind of electrochemical sensor that uses membrane potential to measure the activity or concentration of ions in the solution. When it comes into contact with the solution containing the ions which are to be measured, it will generate contact with the sensor at the interface between its sensitive
    membrane and the solution. Ion activity is directly related to membrane potential. Ion selective electrodes are also called membrane electrodes. This type of electrode has a special electrode membrane that selectively responds to specific ions.
  • Digital sensor Fluoride Chloride Chloride Potassium Nitrate ion for wastewater sensor CS6710AD

    Digital sensor Fluoride Chloride Chloride Potassium Nitrate ion for wastewater sensor CS6710AD

    CS6710AD digital fluoride ion sensor uses a solid membrane ion selective electrode for testing fluoride ions floating in
    water, which is fast, simple, accurate and economical.
    The design adopts the principle of single-chip solid ion selective electrode, with high measurement accuracy. Double salt
    bridge design, longer service life.
    The patented fluoride ion probe, with an internal reference fluid at a pressure of at least 100KPa (1Bar), seeps extremely
    slowly from the microporous salt bridge. Such a reference system is very stable and the electrode life is longer than the ordinary.
  • Digital ISE Sensor Series CS6712SD

    Digital ISE Sensor Series CS6712SD

    The CS6712SD potassium ion selective electrode is an effective method to measure the potassium ion content in the sample. Potassium ion selective electrodes are also often used in online instruments, such as industrial online potassium ion content monitoring. , Potassium ion selective electrode has the advantages of simple measurement, fast and accurate response. It can be used with PH meter, ion meter and online potassium ion analyzer, and also used in electrolyte analyzer, and ion selective electrode detector of flow injection analyzer.
  • Digital RS485 Nitrate Ion Selective Sensor NO3- Electrode Probe 4~20mA Output CS6720SD

    Digital RS485 Nitrate Ion Selective Sensor NO3- Electrode Probe 4~20mA Output CS6720SD

    Ion selective electrode is a kind of electrochemical sensor that uses membrane potential to measure the activity or concentration of ions in the solution. When it comes into contact with the solution containing the ions which are to be measured, it will generate contact with the sensor at the interface between its sensitive
    membrane and the solution. Ion activity is directly related to membrane potential. Ion selective electrodes are also called membrane electrodes. This type of electrode has a special electrode membrane that selectively responds to specific ions.
  • Digital Ammonium Ion Selective Sensor NH4 Electrode RS485 CS6714SD

    Digital Ammonium Ion Selective Sensor NH4 Electrode RS485 CS6714SD

    An electrochemical sensor for determining the activity or concentration of ions in a solution using a membrane potential. When it is in contact with a solution containing the measured ion, a membrane potential directly related to the activity of the ion is generated at the phase interface between its sensitive membrane and the solution. ion selective electrodes are one-half batteries (except gas-sensitive electrodes) that must be composed of complete electrochemical cells with appropriate reference electrodes.
  • Digital Ammonium Nitrogen Ion Selective Sensor NH3+ pH Sensor CS6714AD

    Digital Ammonium Nitrogen Ion Selective Sensor NH3+ pH Sensor CS6714AD

    An electrochemical sensor for determining the activity or concentration of ions in a solution using a membrane potential. When it is in contact with a solution containing the measured ion, a membrane potential directly related to the activity of the ion is generated at the phase interface between its sensitive membrane and the solution. ion selective electrodes are one-half batteries (except gas-sensitive electrodes) that must be composed of complete electrochemical cells with appropriate reference electrodes.
  • Online Digital NH3-N Potassium Ion Compensation Ammonia Nitrogen Sensor RS485

    Online Digital NH3-N Potassium Ion Compensation Ammonia Nitrogen Sensor RS485

    On-line ammonia nitrogen sensor, no reagents required, green and non-polluting, can be monitored online in real time. Integrated ammonium, potassium (optional), pH and reference electrodes automatically compensate for potassium (optional), pH and temperature in water. It can be directly put into installation,which is more economical, environmentally friendly and convenient than traditional ammonia nitrogen analyzer. The sensor has a self-cleaning brush
    that prevents microbial adhesion, resulting in longer maintenance intervals and excellent reliability. It adopts RS485 output and supports Modbus for easy integration.
  • CE Digital Salinity/Ec/Conductivity Meter Ultra Pure Water Sensor CS3743D

    CE Digital Salinity/Ec/Conductivity Meter Ultra Pure Water Sensor CS3743D

    For continuous monitoring and control of conductivity / TDS and temperature values of aqueous solutions. Widely used in power plants, petrochemical, metallurgy, paper industry, environmental water treatmen and other fields. For example, monitoring and control of raw water and water quality of water production equipment such as recharge water, saturated water, condensate water and furnace water, ion exchange, reverse osmosis EDL,seawater distillation
  • pH/ORP Sensor Digital Glass pH ORP Probe Sensor Electrode CS2543D

    pH/ORP Sensor Digital Glass pH ORP Probe Sensor Electrode CS2543D

    Double salt bridge design, double layer seepage interface, resistant to medium reverse seepage. The ceramic pore parameter electrode oozes out of the interface and is not easy to be blocked, which is suitable for monitoring of common water quality environmental media.
  • CS1778D Digital pH Sensor

    CS1778D Digital pH Sensor

    Designed for flue gas desulfurization environment.
    Easy to connect to PLC, DCS, industrial control computers, general purpose controllers, paperless recording instruments or touch screens and other third party devices.