Home
About us
Company profile
Company certificate
Products
laboratory series
Pen Type
Portable
Laboratory
Multi-parameter Monitor Series
Digital Transmitter and Sensors Series
Digital pH Sensor
Digital ORP Sensor
Digital Ion Selective Sensor
Digital Conductivity Sensor
Digital Dissolved Oxygen Sensor
Digital Residual Chlorine Sensor
Digital Suspended Solids(Sludge Concentration) Sensor
Digital Turbidity Sensor
Digital Chlorophyll Analyzer
Digital Blue-Green Algae Analyzer
Digital COD Sensor
pH/ORP/ION Series
pH/ORP Transmitter
Ion Transmitter/Ion Sensor
Conductivity/TDS/Resistivity/Salinity Series
Conductivity Transmitter
Acid-base salt concentration Transmitter
Dissolved Oxygen Series
Fluorescent Dissolved Oxygen Transmitter
Polarography Dissolved Oxygen Transmitter
Micro Dissolved Oxygen Transmitter
Suspended Solids(Sludge Concentration)/Turbidity Series
Suspended Solids(Sludge Concentration) Transmitter
Turbidity Transmitter/Turbidity Sensor
Disinfectant water monitoring series
Residual Chlorine Transmitter
Chlorine Dioxide Transmitter
Dissolved Ozone Transmitter
Ultrasonic Series
Liquid Level Meter
Sludge Interface Meter
Application
Field Installation
News
Support
After Sales Service
Download
CE Certificate
Operation manual
Conductivity&TDS& Resistivity& Salinity
Dissolved Oxygen Series
Ion Concentrations Series
PH&ORP Series
Residual Chlorine& Chlorine Dioxide& Dissolved Ozone
Turbidity&Suspended Solids Series
FAQs
Contact us
English
ALL PRODUCT CATEGORIES
Disinfectant water monitoring series
Potentiostatic Portable Interior Multi Gas Analyzers CS6530
Specifications
Measuring Range:0 - 5.000 mg/L, 0 - 20.00 mg/L
Temperature Range:0 - 50°C
Double liquid junction,annular liquid junction
Temperature sensor: standard no, optional
Housing/dimensions: glass,120mm*Φ12.7mm
Wire: wire length 5m or agreed, terminal
Measurement method: tri-electrode method
Connection thread:PG13.5
This electrode is used with a flow tank.
inquiry
detail
CS5560 CE Certification Digital Chlorine Dioxide Sensor for Waste water RS485
Specifications
Measuring Range:0 - 5.000 mg/L, 0 - 20.00 mg/L
Temperature Range:0 - 50°C
Double liquid junction,annular liquid junction
Temperature sensor: standard no, optional
Housing/dimensions: glass,120mm*Φ12.7mm
Wire: wire length 5m or agreed, terminal
Measurement method: tri-electrode method
Connection thread:PG13.5
This electrode is used with a flow channel.SNEX Solid Reference System pH Sensor for Seawater Measurement
inquiry
detail
Industrial Residual Online Free Chlorine Analyzer 4-20ma Chlorine Meter Sensor Electrode CS5763
CS5763 is an online intelligent residual chlorine controller produced by our company with imported technology. It uses imported components and permeable filmhead, based on the latest polarographic analysis technology, advanced production technology and surface paste technology. The application of this series of adcanced analytical techniques to ensure the stability, reliability and accuracy of the long-term work of the instrument.Widely used in drinking water, bottling water, electricity, medicine, chemical, food, pulp &paper, swimming pool,water treatment industry.
inquiry
detail
Online Dissolved Ozone Meter Analyser T6058
Online Dissolved Ozone meter is a microprocessor-based water quality online monitoring control instrument. It is widely used in drinking water treatment plants, drinking water distribution networks, swimming pools, water treatment projects, sewage treatment, water disinfection and other industrial processes. It continuous monitoring and control Dissolved Ozone value in aqueous solution.
inquiry
detail
Online Dissolved Ozone Meter T4058 Analyser
Online dissolved ozone meter is a microprocessor-based water quality online monitoring control instrument.
Typical Use
This instrument is widely used in online monitoring of water supply, tap water, rural drinking water, circulating water, washing film water, disinfectant water, pool water. It continuous monitoring and control water quality disinfection (ozone generator matching) and other industrial processes.
Features
1. Large display, standard 485 communication, with online and offline alarm, 98*98*120mm meter size, 92.5*92.5mm hole size,3.0 inch large screen display.
2. The data curve recording function is installed, the machine replaces the manual meter reading, and the query range is arbitrarily specified, so that the data is no longer lost.
3. Built-in various measurement functions, one machine with multiple functions, meeting the requirements of various measurement standards.
inquiry
detail
Online Dissolved Ozone Meter Analyser T6558
Function
Online dissolved ozone meter is a microprocessor-based water quality
online monitoring control instrument.
Typical Use
This instrument is widely used in online monitoring of water supply, tap
water, rural drinking water, circulating water, washing film water,
disinfectant water, pool water. It continuous monitoring and control water
quality disinfection (ozone generator matching) and other industrial
processes.
inquiry
detail
CS6530 Potentiostatic Dissolved Ozone Sensor Analyser
Specifications
Measuring Range:0 - 5.000 mg/L, 0 - 20.00 mg/L Temperature Range:0 - 50°C
Double liquid junction,annular liquid junction Temperature sensor: standard no, optional Housing/dimensions: glass,120mm*Φ12.7mm Wire: wire length 5m or agreed, terminal Measurement method: tri-electrode method Connection thread:PG13.5
inquiry
detail
Manufacturer Digital Dissolved O3 Ozone Sensor Water Monitor Meter CS6530D
Potentiostatic method electrode is used to measure residual chlorine or dissolved ozone in water. The potentiostatic method measurement method is to maintain a stable potential at the electrode measuring end, and different measured components produce different current intensities under this potential. It consists of two platinum electrodes and a reference electrode to form a micro current measurement system. The residual chlorine or dissolved ozone in the water sample flowing through the measuring electrode will be consumed. Therefore, the water sample must be kept flowing continuously through the measuring electrode during measurement. The potentiostatic method measurement method uses a secondary instrument to continuously and dynamically control the potential between the measuring electrodes, eliminating the inherent resistance and oxidation-reduction potential of the measured water sample, so that the electrode can measure the current signal and the measured water sample concentration A good linear relationship is formed between them, with a very stable zero point performance, ensuring accurate and reliable measurement
inquiry
detail
Online Residual Chlorine Meter Digital Analyzer Free Chlorine Controller for Water T6575
The online suspended solids meter is an online analytical instrument designed to measure the sludge concentration of water from waterworks, municipal pipeline network, industrial process water quality monitoring, circulating cooling water, activated carbon filter effluent, membrane filtration effluent, etc. especially in the treatment of municipal sewage or industrial wastewater. Whether evaluating
activated sludge and the entire biological treatment process, analyzing wastewater discharged after purification treatment, or detecting sludge concentration at different stages, the sludge concentration meter can give continuous and accurate measurement results.
inquiry
detail
Industrial Online Waterproof Digital Dissolved Ozone Sensor CS6530D
Potentiostatic principle electrode is used to measure dissolved ozone in water. The potentiostatic measurement method is to maintain a stable potential at the electrode measuring end, and different measured components produce different current intensities under this potential. It consists of two platinum electrodes and a reference electrode to form a micro current measurement system. The dissolved ozone in the water sample flowing through the measuring electrode will be consumed.
inquiry
detail
Online Digital Chlorine Dioxide Sensor for Disinfectant Fluid RS485 CS5560D
Constant voltage principle electrode is used to measure chlorine dioxide or hypochlorous acid in water. The constant voltage measurement method is to maintain a stable potential at the electrode measuring end, and different measured components produce different current intensities under this potential.
inquiry
detail
Online Membrane Residual Chlorine Meter T4055
Online residual chlorine meter is a microprocessor-based water quality online monitoring control instrument.
inquiry
detail
1
2
Next >
>>
Page 1 / 2
Hit enter to search or ESC to close
English
French
German
Portuguese
Spanish
Russian
Japanese
Korean
Arabic
Irish
Greek
Turkish
Italian
Danish
Romanian
Indonesian
Czech
Afrikaans
Swedish
Polish
Basque
Catalan
Esperanto
Hindi
Lao
Albanian
Amharic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Bulgarian
Cebuano
Chichewa
Corsican
Croatian
Dutch
Estonian
Filipino
Finnish
Frisian
Galician
Georgian
Gujarati
Haitian
Hausa
Hawaiian
Hebrew
Hmong
Hungarian
Icelandic
Igbo
Javanese
Kannada
Kazakh
Khmer
Kurdish
Kyrgyz
Latin
Latvian
Lithuanian
Luxembou..
Macedonian
Malagasy
Malay
Malayalam
Maltese
Maori
Marathi
Mongolian
Burmese
Nepali
Norwegian
Pashto
Persian
Punjabi
Serbian
Sesotho
Sinhala
Slovak
Slovenian
Somali
Samoan
Scots Gaelic
Shona
Sindhi
Sundanese
Swahili
Tajik
Tamil
Telugu
Thai
Ukrainian
Urdu
Uzbek
Vietnamese
Welsh
Xhosa
Yiddish
Yoruba
Zulu
Kinyarwanda
Tatar
Oriya
Turkmen
Uyghur