We are proud of the high customer satisfaction and wide acceptance due to our persistent pursuit of high quality both on product and service for Real Time Water Monitoring System, Polarographic Oxygen Electrode, Waterproof Pen Type TDS Tester, We, with open arms, invite all interested buyers to visit our website or contact us directly for further information.
factory low price Minimum Chlorine Residual - Digital Turbidity Sensor with Automatic Cleaning – Chunye Detail:

The principle of the turbidity sensor is based on the combined infrared absorption and scattered light method. The ISO7027 method can be used to continuously and accurately determine the turbidity value. According to ISO7027 infrared double-scattering light technology is not affected by chromaticity to determine the sludge concentration value. The self-cleaning function can be selected according to the use environment. Stable data, reliable performance; built-in self-diagnosis function to ensure accurate data; simple installation and calibration.

The electrode body is made of 316L stainless steel, which is corrosion-resistant and more durable. The seawater version can be plated with titanium, which also performs well under strong corrosion. Fully automatic electrode scraper, self-cleaning function, effectively prevent solid particles from covering the lens, improve measurement accuracy, and prolong use accuracy.

IP68 waterproof design, can be used for input measurement. Real-time online recording of Turbidity/MLSS/SS, temperature data and curves, compatible with all water quality meters of our company.

Turbidity monitoring of water from waterworks, water quality monitoring of municipal pipeline network; industrial process water quality monitoring, circulating cooling water, activated carbon filter effluent, membrane filtration effluent, etc.

The internal upgrade of the sensor can effectively prevent the internal circuit from dampness and dust accumulation, and avoid damage to the internal circuit.

The transmitted light adopts stable invisible near-monochromatic infrared light source, which avoids the interference of chroma in liquid and external visible light to sensor measurement.And built-in luminosity compensation, improve the measurement accuracy.

The use of quartz glass lens with high light transmittance in the optical path makes the transmission and reception of infrared light waves more stable.

Wide range, stable measurement, high precision, good reproducibility.

Communication functions: Two photoelectric isolation signal output, one RS-485 communication interface (Modbus-RTU protocol compatible), the fastest communication interval is 50ms.One way 4 ~ 20mA current output, 4-20mA can reverse output; No instrument, can be directly connected to computers, PLC and other devices with RS485/4-20mA signal interface for data acquisition. It is convenient for users to integrate the sensor into the upper computer system and the IoT system and other industrial control environment.

Without meter, the sensor can be set online through software, from the machine address and baud rate, online calibration, restore factory, 4-20mA output corresponding range, modify the range, proportional coefficient and incremental compensation Settings.

Model No.

CS7833D

Power/Outlet

9~36VDC/RS485 MODBUS RTU

Measurement mode

90°+135°IR scattered light method, infrared dual beam

Dimensions

Diameter 50mm*Length 223mm

Housing material

PVC+316 Stainless steel

Waterproof rating

IP68

Measurement range

2-4000 NTU

Measurement accuracy

±1%

Pressure resistance

≤0.3Mpa

Measuring temperature

0-45℃

Calibration

Standard liquid calibration, water sample calibration

Cable length

Standard 10m,can be extended to 100m

Thread

1 inch

Weight

2.0kg

Application

General applications, rivers, lakes, environmental protection, etc.


Product detail pictures:

factory low price Minimum Chlorine Residual - Digital Turbidity Sensor with Automatic Cleaning – Chunye detail pictures

factory low price Minimum Chlorine Residual - Digital Turbidity Sensor with Automatic Cleaning – Chunye detail pictures


Related Product Guide:

"Control the standard by the details, show the power by quality". Our business has strived to establish a highly efficient and stable team staff and explored an effective good quality regulate course of action for factory low price Minimum Chlorine Residual - Digital Turbidity Sensor with Automatic Cleaning – Chunye , The product will supply to all over the world, such as: Portugal, Costa Rica, Namibia, They're durable modeling and promoting well all over the world. Under no circumstances disappearing key functions in a brief time, it's a should for you personally of fantastic quality. Guided by the principle of Prudence, Efficiency, Union and Innovation. the business make an awesome efforts to expand its international trade, raise its enterprise. rofit and improve its export scale. We are confident that we'll have a vibrant prospect and to be distributed all over the world in the years to come.
  • We feel easy to cooperate with this company, the supplier is very responsible, thanks.There will be more in-depth cooperation.
    5 Stars By Nancy from Korea - 2018.12.05 13:53
    This company can be well to meet our needs on product quantity and delivery time, so we always choose them when we have procurement requirements.
    5 Stars By Letitia from Riyadh - 2018.10.01 14:14
    Write your message here and send it to us