Our growth depends to the superior products ,great talents and repeatedly strengthened technology forces for Chlorophyll Analyzer, Liquified Natural Gas Environment pH Electrode, Electronic Ph Tester Aquarium, "Quality 1st, Rate least expensive, Provider best" is definitely the spirit of our company. We sincerely welcome you to go to our business and negotiate mutual small business!
Factory made hot-sale Orp Meter In Ro Plant - Online Dissolved Ozone Meter T6058 – Chunye Detail:

Function

Online dissolved ozone meter is a microprocessor-based water quality online monitoring control instrument.

Typical Use

This instrument is widely used in online monitoring of water supply, tap water, rural drinking water, circulating water, washing film water, disinfectant water, pool water. It continuous monitoring and control water quality disinfection (ozone generator matching) and other industrial processes.

Mains Supply

85~265VAC±10%,50±1Hz, power ≤3W;
9~36VDC, power consumption≤3W;

Measuring Range

Chlorine dioxide: 0~20mg/L; 0~20ppm;
Temperature: 0~150℃.

Features

1.Large display, standard 485 communication, with online and offline alarm, 144*144*118mm meter size, 138*138 hole size, 4.3 inch large screen display.

2.The data curve recording function is installed, the machine replaces the manual meter reading, and the query range is arbitrarily specified, so that the data is no longer lost.

3.Historical curve: The dissolved ozone measurement data can be stored automatically every 5 minutes, and the residual chlorine value can be stored continuously for a month. Provide “history curve” display and “fixed point” query function on the same screen.

4.Built-in various measurement functions, one machine with multiple functions, meeting the requirements of various measurement standards.

5.The design of the whole machine is waterproof and dustproof, and the back cover of the connection terminal is added to extend the service life in harsh environments.

6.Panel/wall/pipe installation, three options are available to meet various industrial site installation requirements.

Electrical connections

Electrical connection The connection between the instrument and the sensor: the power supply, output signal, relay alarm contact and the connection between the sensor and the instrument are all inside the instrument. The length of the lead wire for the fixed electrode is usually 5-10 meters, and the corresponding label or color on the sensor Insert the wire into the corresponding terminal inside the instrument and tighten it.

Instrument installation method

11

Technical specifications

Measurement range 0.005~20mg/L;0.005~20.00ppm
Measurement theory Potentiometric method
Resolution 0.001mg/L;0.001ppm
Basic error ±1%F.S
Temperature 0~50.0°C
Temperature resolution 0.1°C
Temperature accuracy ±0.3°C
Temperature compensation 0~60.0°C
Temperature compensation Manual or automatic
Electrode residual signal <1‰
Response time 25°C<60S; 35°C<30S (To attain 90%)
Stability At constant pressure and temperature, the weekly drift<2%F•S;
Current output Two:4~20mA,20~4mA,0~20mA(load resistance<750Ω)
Communication output RS485 MODBUS RTU
Relay control set-points Three:3A 250VAC,3A 30VDC
Optional power supply 85~265VAC,9~36VDC,power consumption≤3W
Working conditions No strong magnetic field interference except the geomagnetic field.
Working temperature -10~60°C
Relative humidity ≤90%
Waterproof rating IP65
Weight 0.8kg
Dimensions 144×144×118mm
Installation opening size 138×138mm
Installation methods Panel, wall mounting or pipeline

 

1

Model No.

CS6530

Measurement method

Tri-electrode method

Measure material

Double liquid junction,annular liquid junction

Housing material/Dimensions

PP, Glass, 120mm*Φ12.7mm

Waterproof grade

IP68

Measurement range

0 – 5.000 mg/L, 0 – 20.00 mg/L

Accuracy

±0.05mg/L;

Pressure resistance

≤0.3Mpa

Temperature compensation

None or Customize NTC10K

Temperature range

0-50℃

Calibration

Sample calibration

Connection methods

4 core cable

Cable length

Standard 5m cable, can be extended to 100m

Installation thread

PG13.5

Application

Tap water, disinfectant fluid, etc.

 


Product detail pictures:

Factory made hot-sale Orp Meter In Ro Plant - Online Dissolved Ozone Meter T6058 – Chunye detail pictures

Factory made hot-sale Orp Meter In Ro Plant - Online Dissolved Ozone Meter T6058 – Chunye detail pictures

Factory made hot-sale Orp Meter In Ro Plant - Online Dissolved Ozone Meter T6058 – Chunye detail pictures


Related Product Guide:

Like a result of ours specialty and repair consciousness, our enterprise has won a superb popularity amid buyers everywhere in the environment for Factory made hot-sale Orp Meter In Ro Plant - Online Dissolved Ozone Meter T6058 – Chunye , The product will supply to all over the world, such as: Croatia, Albania, Naples, Besides there are also experienced production and management , advanced production equipment to assure our quality and delivery time , our company pursues the principle of good faith, high-quality and high-efficiency. We guarantee that our company will try our best to reduce customer purchase cost, shorten the period of purchase, stable solutions quality, increase customers' satisfaction and achieve win-win situation .
  • This enterprise in the industry is strong and competitive, advancing with the times and develop sustainable, we are very pleased to have a opportunity to cooperate!
    5 Stars By Rosalind from Guyana - 2017.09.30 16:36
    The enterprise has a strong capital and competitive power, product is sufficient, reliable, so we have no worries on cooperating with them.
    5 Stars By jari dedenroth from Macedonia - 2017.09.29 11:19
    Write your message here and send it to us