Factory selling Residual Chlorine And Free Chlorine - Online Dissolved Oxygen Meter T6046 – Chunye Detail:
Function
Industrial online dissolved oxygen meter is an online water quality monitor and control instrument with microprocessor. The instrument is equipped with fluorescent dissolved oxygen sensors. The online dissolved oxygen meter is a highly intelligent online continuous monitor. It can be equipped with fluorescent electrodes to automatically achieve a wide range of ppm measurement. It is a special instrument for detecting oxygen content in liquids in environmental protection sewage related industries.
Typical Use
The online dissolved oxygen meter is a special instrument for detecting oxygen content in liquids in environmental protection sewage related industries. It has the characteristics of fast response, stability, reliability, and low use cost, and is suitable for large-scale use in water plants, aeration tanks, aquaculture, and sewage treatment plants.
Mains Supply
85~265VAC±10%,50±1Hz, power ≤3W;
9~36VDC, power consumption≤3W;
Measuring Range
Dissolved Oxygen: 0~40mg/L, 0~400%;
Customizable measuring range, displayed in ppm unit.
Online Dissolved Oxygen Meter T6046
Features
1.Large display, standard 485 communication, with online and offline alarm, 144*144*118mm meter size, 138*138mm hole size, 4.3 inch large screen display.
2.Fluorescent dissolved oxygen electrode adopts optical physics principle, no chemical reaction in the measurement, no influence of bubbles, aeration/anaerobic tank installation and measurement are more stable, maintenance-free in the later period, and more convenient to use.
3.The data curve recording function is installed, the machine replaces the manual meter reading, and the query range is arbitrarily specified, so that the data is no longer lost.
4.Carefully select materials and strictly select each circuit component, which greatly improves the stability of the circuit during long-term operation.
5.The new choke inductance of the power board can effectively reduce the influence of electromagnetic interference, and the data is more stable.
6.The design of the whole machine is waterproof and dustproof, and the back cover of the connection terminal is added to extend the service life in harsh environments.
7.Panel/wall/pipe installation, three options are available to meet various industrial site installation requirements.
Electrical connections
Electrical connection The connection between the instrument and the sensor: the power supply, output signal, relay alarm contact and the connection between the sensor and the instrument are all inside the instrument. The length of the lead wire for the fixed electrode is usually 5-10 meters, and the corresponding label or color on the sensor Insert the wire into the corresponding terminal inside the instrument and tighten it.
Instrument installation method
Technical specifications
Measurement range | 0~40.00mg/L; 0~400.0% |
Measurement unit | mg/L; % |
Resolution | 0.01mg/L; 0.1% |
Basic error | ±1%F.S |
Temperature | -10~150℃ |
Temperature Resolution | 0.1℃ |
Temperature Basic error | ±0.3℃ |
Current Output | 4~20mA,20~4mA,(load resistance<750Ω) |
Communication output | RS485 MODBUS RTU |
Relay control contacts | 5A 240VAC,5A 28VDC or 120VAC |
Power supply (optional) | 85~265VAC,9~36VDC,power consumption≤3W |
Working conditions | No strong magnetic field interference around except the geomagnetic field. |
Working temperature | -10~60℃ |
Relative humidity | ≤90% |
IP rate | IP65 |
Instrument Weight | 0.8kg |
Instrument Dimensions | 144×144×118mm |
Mounting hole dimensions | 138*138mm |
Installation methods | Panel,Wall mounted,pipeline |
Order Number
Model No. |
CS4760D |
Power/Output |
9~36VDC/RS485 MODBUS RTU |
Measuring Mode |
Fluorescence method |
Housing Material |
POM+316LStainless steel |
Waterproof Rating |
IP68 |
Measuring Range |
0-20mg/L |
Accuracy |
±1%F.S |
Pressure Range |
≤0.3Mpa |
TemperatureCompensation | NTC10K |
Temperature Range |
0-50℃ |
Calibration |
Anaerobic Water Calibration and Air Calibration |
Connection Method |
4 core cable |
Cable Length |
Standard 10m cable, can be extended |
Installation Thread |
G3/4’’ |
Application |
General application, river, lake,drink water, environment protection ,etc |
Product detail pictures:
Related Product Guide:
Our primary target will be to provide our clients a serious and responsible small business relationship, supplying personalized attention to all of them for Factory selling Residual Chlorine And Free Chlorine - Online Dissolved Oxygen Meter T6046 – Chunye , The product will supply to all over the world, such as: Puerto Rico, Senegal, France, Wide selection and fast delivery to suit your needs! Our philosophy: Good quality, great service, keep improving. We've been looking forward that more and more oversea friends join in our family for further development near the future!
By Beulah from Lesotho - 2018.06.30 17:29
With a positive attitude of "regard the market, regard the custom, regard the science", the company works actively to do research and development. Hope we have a future business relationships and achieving mutual success.
By Michelle from Canada - 2017.06.22 12:49