Good quality Atc Ph Tester - Online Membrane Residual Chlorine Meter T6555 – Chunye

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We believe that prolonged expression partnership is really a result of top of the range, value added support, rich encounter and personal contact for Ozone Gas Monitor, TDS Tester Meter, Electronic Soil Ph Tester, We welcome customers all over the word to contact us for future business relationships. Our products are the best. Once Selected, Perfect Forever!
Good quality Atc Ph Tester - Online Membrane Residual Chlorine Meter T6555 – Chunye Detail:

Function

Online residual chlorine meter is a microprocessor-based water quality online monitoring control instrument.

Typical Use

This instrument is widely used in online monitoring of water supply, tap water, rural drinking water, circulating water, washing film water, disinfectant water, pool water. and other industrial processes. It continuous monitoring and control residual chlorine, pH and temperature value in aqueous solution.

Mains Supply

85~265VAC±10%,50±1Hz, power ≤3W;
9~36VDC, power consumption≤3W;

Measuring Range

Residual Chlorine: 0~20ppm;
pH: -2~16pH;
Temperature: 0~150℃.

Features

1.Large display, standard 485 communication, with online and offline alarm, 235*185*120mm meter size, 7.0 inch large screen display.

2.The data curve recording function is installed, the machine replaces the manual meter reading, and the query range is arbitrarily specified, so that the data is no longer lost.

3.Historical curve: The residual chlorine measurement data can be stored automatically every 5 minutes, and the residual chlorine value can be stored continuously for a month. Provide “history curve” display and “fixed point” query function on the same screen.

4.Built-in various measurement functions, one machine with multiple functions, meeting the requirements of various measurement standards.

5.The design of the whole machine is waterproof and dustproof, and the back cover of the connection terminal is added to extend the service life in harsh environments.

Electrical connections

Electrical connection The connection between the instrument and the sensor: the power supply, output signal, relay alarm contact and the connection between the sensor and the instrument are all inside the instrument. The length of the lead wire for the fixed electrode is usually 5-10 meters, and the corresponding label or color on the sensor Insert the wire into the corresponding terminal inside the instrument and tighten it.

Instrument installation method

bbb

Technical specifications

Measurement range 0.005~20.00mg/L ; 0.005~20.00ppm
Measurement unit Membrane
Resolution 0.001mg/L ; 0.001ppm
Basic error ±1%F.S։
Measurement range -2 16.00pH
Measurement unit pH
Resolution 0.001pH
Basic error ±0.01pH։ ˫
Temperature -10 150.0 ( Based on sensor)˫
Temperature Resolution 0.1˫
Temperature Basic error ±0.3։
Current output 2 groups: 4 20mA
Signal output RS485 Modbus RTU
Other functions Data record &Curve display
Three relay control contacts 3 groups:5A 250VAC,5A 30VDC
Optional power supply 85~265VAC,9~36VDC,power consumption≤3W
Working conditions No strong magnetic field interference around except the geomagnetic field.։ ˫
Working temperature -10 60
Relative humidity ≤90%
Waterproof rating IP65
Weight 1.5kg
Dimensions 235×185×120mm
Installation methods Wall mounted

 

 

b1

Model No.

CS5763

Measurement method

Membrane

Housing material

POM+316L Stainless

Waterproof grade

IP68

Measurement range

0 – 20.00 mg/L

Accuracy

±0.05mg/L;

Pressure resistance

≤0.3Mpa

Temperature compensation

NTC10K

Temperature range

0-50℃

Calibration

Chlorine-free water, water sample calibration

Connection methods

4 core cable

Cable length

Standard 5m cable, can be extended to 100m

Installation thread

NPT3/4’’

Application

Tap water, disinfectant fluid, etc.

Product detail pictures:

Good quality Atc Ph Tester - Online Membrane Residual Chlorine Meter T6555 – Chunye detail pictures

Good quality Atc Ph Tester - Online Membrane Residual Chlorine Meter T6555 – Chunye detail pictures

Good quality Atc Ph Tester - Online Membrane Residual Chlorine Meter T6555 – Chunye detail pictures


Related Product Guide:

Using a full scientific good quality administration system, very good quality and superior faith, we win good standing and occupied this discipline for Good quality Atc Ph Tester - Online Membrane Residual Chlorine Meter T6555 – Chunye , The product will supply to all over the world, such as: Houston, Zambia, Madagascar, If you are for any reason unsure which product to select, do not hesitate to contact us and we are going to be delighted to advise and assist you. This way we are going to be providing you with all the knowledge needed to make the best choice. Our company strictly follows "Survive by good quality, Develop by keeping good credit. " operation policy. Welcome all the clients old and new to visit our company and talk about the business. We have been looking for more and more customers to create the glorious future.
  • Reasonable price, good attitude of consultation, finally we achieve a win-win situation,a happy cooperation!
    5 Stars By Philipppa from Algeria - 2017.03.08 14:45
    This supplier's raw material quality is stable and reliable, has always been in accordance with the requirements of our company to provide the goods that quality meet our requirements.
    5 Stars By Penelope from Portugal - 2017.11.12 12:31
    Write your message here and send it to us