High Performance Use Of Ec Meter - Online Residual Chlorine Meter T6050 – Chunye

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our solutions are widely regarded and trustworthy by consumers and may meet continually modifying financial and social requirements for Ultrasonic Liquid Level Meter, Water Conductivity Sensor, Water Turbidity Sensor, First business, we learn each other. Further business, the trust is getting there. Our company always at your service at any time.
High Performance Use Of Ec Meter - Online Residual Chlorine Meter T6050 – Chunye Detail:

Function

Online residual chlorine meter is a microprocessor-based water quality online monitoring control instrument.

Typical Use

This instrument is widely used in online monitoring of water supply, tap water, rural drinking water, circulating water, washing film water, disinfectant water, pool water. and other industrial processes. It continuous monitoring and control residual chlorine and  temperature  value  in aqueous solution.

Mains Supply

85~265VAC±10%,50±1Hz, power ≤3W;
9~36VDC, power consumption≤3W;

Measuring Range

Residual Chlorine: 0~20ppm; 0~20mg/L;
Temperature: 0~150℃.

Features

1.Large display, standard 485 communication, with online and offline alarm, 144*144*118mm meter size, 138*138mm hole size, 4.3 inch large screen display.

2.The data curve recording function is installed, the machine replaces the manual meter reading, and the query range is arbitrarily specified, so that the data is no longer lost.

3.Historical curve: The residual chlorine measurement data can be stored automatically every 5 minutes, and the residual chlorine value can be stored continuously for a month. Provide “history curve” display and “fixed point” query function on the same screen.

4.Built-in various measurement functions, one machine with multiple functions, meeting the requirements of various measurement standards.

5.The design of the whole machine is waterproof and dustproof, and the back cover of the connection terminal is added to extend the service life in harsh environments.

6.Panel/wall/pipe installation, three options are available to meet various industrial site installation requirements.

Electrical connections

Electrical connection The connection between the instrument and the sensor: the power supply, output signal, relay alarm contact and the connection between the sensor and the instrument are all inside the instrument. The length of the lead wire for the fixed electrode is usually 5-10 meters, and the corresponding label or color on the sensor Insert the wire into the corresponding terminal inside the instrument and tighten it.

Instrument installation method

aaa

Technical specifications

Measurement range 0.005~20.00mg/L ; 0.005~20.00ppm
Measurement unit Potentiometric method
Resolution 0.001mg/L ; 0.001ppm
Basic error ±1%F.S

։ ˫

Temperature -10 150.0 ( Based on sensor)

˫

Temperature Resolution 0.1

˫

Temperature Basic error ±0.3

։

Current output 2 groups: 4 20mA
Signal output RS485 Modbus RTU
Other functions Data record &Curve display
Three relay control contacts 3 groups:5A 250VAC,5A 30VDC
Optional power supply 85~265VAC,9~36VDC,power consumption≤3W
Working conditions No strong magnetic field interference around except the geomagnetic field.

։ ˫

Working temperature -10 60
Relative humidity ≤90%
Waterproof rating IP65
Weight 0.8kg
Dimensions 144×144×118mm
Installation opening size 138×138mm
Installation methods Panel & wall mounted or pipeline

1

Model No.

CS5530

Measurement method

Tri-electrode method

Measure material

Double liquid junction,annular liquid junction

Housing material/Dimensions

PP, Glass, 120mm*Φ12.7mm

Waterproof grade

IP68

Measurement range

0 – 5.000 mg/L, 0 – 20.00 mg/L

Accuracy

±0.05mg/L;

Pressure resistance

≤0.3Mpa

Temperature compensation

None or Customize NTC10K

Temperature range

0-50℃

Calibration

Sample calibration

Connection methods

4 core cable

Cable length

Standard 5m cable, can be extended to 100m

Installation thread

PG13.5

Application

Tap water, disinfectant fluid, etc.

 


Product detail pictures:

High Performance Use Of Ec Meter - Online Residual Chlorine Meter T6050 – Chunye detail pictures

High Performance Use Of Ec Meter - Online Residual Chlorine Meter T6050 – Chunye detail pictures

High Performance Use Of Ec Meter - Online Residual Chlorine Meter T6050 – Chunye detail pictures


Related Product Guide:

To be a result of ours specialty and service consciousness, our company has won a superb reputation between customers all around the environment for High Performance Use Of Ec Meter - Online Residual Chlorine Meter T6050 – Chunye , The product will supply to all over the world, such as: Georgia, Manila, Rio de Janeiro, Further, we are supported by highly experienced and knowledgeable professionals, who have immense expertise in their respective domain. These professionals work in close coordination with each other to offer our clients an effective range of products.
  • The supplier abide the theory of "quality the basic, trust the first and management the advanced" so that they can ensure a reliable product quality and stable customers.
    5 Stars By Tyler Larson from Slovak Republic - 2018.06.12 16:22
    The company's products can meet our diverse needs, and the price is cheap, the most important is that the quality is also very nice.
    5 Stars By Cindy from Mecca - 2018.06.18 17:25
    Write your message here and send it to us