Massive Selection for Simple Operation Handheld Salinity Meter - Online Dissolved Oxygen Meter T4042 – Chunye

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We are convinced that with joint endeavours, the small business between us will bring us mutual benefits. We could assure you products quality and competitive selling price for Environmental Portable Dissolved Ozone Tester Meter, Atc Ph Tester, Flat Bottom Ph Electrode, As a result of our hard perform, we have always been around the forefront of clean technology merchandise innovation. We've been a eco-friendly partner you can rely on. Get hold of us today for additional data!
Massive Selection for Simple Operation Handheld Salinity Meter - Online Dissolved Oxygen Meter T4042 – Chunye Detail:

T4042
4000-A
4000-B
Function
Industrial online dissolved oxygen meter is an online water quality monitor and control instrument with microprocessor. The instrument is equipped with different types of dissolved oxygen sensors. It is widely used in power plants, petrochemical industry, metallurgical electronics, mining, paper industry, food and beverage industry, environmental protection water treatment, aquaculture and other industries. The dissolved oxygen value and temperature value of water solution are continuously monitored and controlled.
Typical Use
This instrument is a special instrument for detecting oxygen content in liquids in environmental protection sewage related industries. It has the characteristics of fast response, stability, reliability, and low use cost, widely used in large-scale water plants, aeration tanks, aquaculture, and sewage treatment plants.
Mains Supply
85~265VAC±10%,50±1Hz, power ≤3W;
9~36VDC, power consumption≤3W;
Measuring Range

Dissolved Oxygen: 0~200ug/L, 0~20mg/L;
Customizable measuring range, displayed in ppm unit.

Online Dissolved Oxygen Meter T4042

Features

1.Large display, standard 485 communication, with online and offline alarm, 98*98*130 meter size, 92.5*92.5 hole size, 3.0 inch large screen display.

2.The default English parameter settings, the function description is concise and clear, in line with most people’s operating habits, and provide convenience for operators.

3.Carefully select materials and strictly select each circuit component, which greatly improves the stability of the circuit during long-term operation.

4.The new choke inductance of the power board can effectively reduce the influence of electromagnetic interference, and the data is more stable.

5.The design of the whole machine is waterproof and dustproof, and the back cover of the connection terminal is added to extend the service life in harsh environments.

6.Panel/wall/pipe installation, three options are available to meet various industrial site installation requirements.

Electrical connections
Electrical connection The connection between the instrument and the sensor: the power supply, output signal, relay alarm contact and the connection between the sensor and the instrument are all inside the instrument. The length of the lead wire for the fixed electrode is usually 5-10 meters, and the corresponding label or color on the sensor Insert the wire into the corresponding terminal inside the instrument and tighten it.
Instrument installation method
11
Technical specifications

Measurement range 0~200ug/L; 0~20mg/L
Measurement unit ug/L; mg/L
Resolution 0.01ug/L; 0.01mg/L
Basic error ±1%F.S
Temperature -10~150℃
Temperature Resolution 0.1℃
Temperature Basic error ±0.3℃
Current Output 4~20mA,20~4mA,(load resistance<750Ω)
Communication output RS485 MODBUS RTU
Relay control contacts 5A 240VAC,5A 28VDC or 120VAC
Power supply (optional) 85~265VAC,9~36VDC,power consumption≤3W
Working conditions No strong magnetic field interference around except the geomagnetic field.
Working temperature -10~60℃
Relative humidity ≤90%
IP rate IP65
Instrument Weight 0.6kg
Instrument Dimensions 98×98×130mm
Mounting hole dimensions 92.5*92.5mm
Installation methods Panel,Wall mounted,pipeline

Dissolved Oxygen Sensor

1

Model No. CS4800
Measuring Mode Polarography
Housing Material 316 Stainless steel
Waterproof Rating IP68
Measuring Range 0-20mg/L
Accuracy ±1%F.S
PressureRange ≤0.3Mpa
Temperature Compensation  NTC10K
Temperature Range 0-80℃
Calibration Anaerobic Water Calibration and Air Calibration
Connection Methods 4 core cable
Cable Length Standard 5m cable, can be extended
Installation Thread Compaction Style
Application Power plant, boiler water, etc

Product detail pictures:

Massive Selection for Simple Operation Handheld Salinity Meter - Online Dissolved Oxygen Meter T4042 – Chunye detail pictures

Massive Selection for Simple Operation Handheld Salinity Meter - Online Dissolved Oxygen Meter T4042 – Chunye detail pictures

Massive Selection for Simple Operation Handheld Salinity Meter - Online Dissolved Oxygen Meter T4042 – Chunye detail pictures


Related Product Guide:

High-quality comes 1st; assistance is foremost; business enterprise is cooperation" is our business enterprise philosophy which is constantly observed and pursued by our business for Massive Selection for Simple Operation Handheld Salinity Meter - Online Dissolved Oxygen Meter T4042 – Chunye , The product will supply to all over the world, such as: Angola, Florida, Greece, We adopted technique and quality system management, based on "customer orientated, reputation first, mutual benefit, develop with joint efforts", welcome friends to communicate and cooperate from all over the world.
  • It is not easy to find such a professional and responsible provider in today's time. Hope that we can maintain long-term cooperation.
    5 Stars By Marian from Seychelles - 2018.07.12 12:19
    The goods we received and the sample sales staff display to us have the same quality, it is really a creditable manufacturer.
    5 Stars By Lisa from Guyana - 2018.06.28 19:27
    Write your message here and send it to us