T9070 Multi-parameter Online Water Quality Monitoring system
Function
This instrument is an intelligent online controller, which is widely used in water quality detection in sewage plants,waterworks,water stations, surface water and other fields, as well as electronic, electroplating, printing and dyeing, chemistry,food, pharmaceutical and other process fields, meet the needs of water quality detection; Adopting digital and modular design,different functions are completed by various unique modules. Built-in more than 20 kinds of sensors, which can be combined at will, and reserved powerful expansion functions.
Typical Use
This instrument is a special instrument for detecting oxygen content in liquids in environmental protection sewage related industries. It has the characteristics of fast response, stability, reliability, and low use cost, widely used in large-scale water plants, aeration tanks, aquaculture, and sewage treatment plants.Designed for online monitoring of water supply and outlet, water quality of pipe network and secondary water supply of residential area.
T9070 Multi-parameter Online Water Quality Monitoring system
Features
2.Multi-parameter on-line monitoring system can support six parameters at the same time. Customizable parameters.
3.Easy to install. The system has only one sample inlet, one waste outlet and one power supply connection;
4.The historical record: Yes
5.Installation mode: Vertical type;
6.The sample flow rate is 400 ~ 600mL/min;
7.4-20mA or DTU remote transmission. GPRS;
Electrical connections
Electrical connection The connection between the instrument and the sensor: the power supply, output signal, relay alarm contact and the connection between the sensor and the instrument are all inside the instrument. The length of the lead wire for the fixed electrode is usually 5-10 meters, and the corresponding label or color on the sensor Insert the wire into the corresponding terminal inside the instrument and tighten it.
Instrument installation method
Technical specification
Project |
Technical Parameters |
Project |
Technical Parameters |
pH |
Dissolved Oxygen |
||
Principle |
Electrochemistry |
Principle |
Fluorescence |
Range |
0~14 pH |
Range |
0~20mg/L ;0~200% |
Accuracy |
±0.3pH |
Accuracy |
±0.5mg/L |
Resolution |
0.01pH |
Resolution |
0.01mg/L |
MTBF |
≥1440H |
MTBF |
≥1440H |
COD |
TSS |
||
Principle |
UV254 |
Principle |
90°+135° IR infrared |
Range |
0~1500mg/L |
Range |
0.01-50000mg/L |
Accuracy |
±5% |
Accuracy |
±5% |
Resolution |
0.01mg/L |
Resolution |
0.01mg/L |
Water Temperature |
|||
Principle |
Thermal resistance |
Accuracy |
±0.2℃ |
Range |
0℃~80℃ |
MTBF |
≥1440H |
Controller |
|||
Dimensions
|
1470*500*400mm |
Power supply |
100~240VAC or 9~36VDC |
IP Grade
|
IP54 or Customize IP65 |
Power |
3W~5W |
Write your message here and send it to us