Online Chlorine Dioxide Meter T6053

Short Description:

Online chlorine dioxide meter is a microprocessor-based water quality online monitoring control instrument.


Product Detail

Product Tags

Online Chlorine Dioxide Meter T6053

T6053
6000-A
6000-B
Function

Online chlorine dioxide meter is a microprocessor-based water quality online monitoring control instrument.

Typical Use

This instrument is widely used in online monitoring of water supply, tap water, rural drinking water, circulating water, washing film water, disinfectant water, pool water. and other industrial processes. It continuous monitoring and control chlorine dioxide and temperature value in aqueous solution.

Mains Supply

85~265VAC±10%,50±1Hz, power ≤3W;
9~36VDC, power consumption≤3W;

Measuring Range

Chlorine dioxide: 0~20mg/L; 0~20ppm;
Temperature: 0~150℃.

Online Chlorine Dioxide Meter T6053

1

Measurement Mode

1

Calibration Mode

1

Trend Chart Display

4

Setting mode

Features

1.Large display, standard 485 communication, with online and offline alarm, 144*144*118mm meter size, 138*138mm hole size, 4.3 inch large screen display.

2.The data curve recording function is installed, the machine replaces the manual meter reading, and the query range is arbitrarily specified, so that the data is no longer lost.

3.Historical curve: The chlorine dioxide measurement data can be stored automatically every 5 minutes, and the residual chlorine value can be stored continuously for a month. Provide "history curve" display and "fixed point" query function on the same screen.

4.Built-in various measurement functions, one machine with multiple functions, meeting the requirements of various measurement standards.

5.The design of the whole machine is waterproof and dustproof, and the back cover of the connection terminal is added to extend the service life in harsh environments.

6.Panel/wall/pipe installation, three options are available to meet various industrial site installation requirements.

Electrical connections

Electrical connection The connection between the instrument and the sensor: the power supply, output signal, relay alarm contact and the connection between the sensor and the instrument are all inside the instrument. The length of the lead wire for the fixed electrode is usually 5-10 meters, and the corresponding label or color on the sensor Insert the wire into the corresponding terminal inside the instrument and tighten it.

Instrument installation method

A1

Technical specifications

Measurement range 0.005~20.00mg/L ; 0.005~20.00ppm
Measurement unit Potentiometric method
Resolution 0.001mg/L ; 0.001ppm
Basic error ±1%F.S

։ ˫

Temperature -10 150.0 ( Based on sensor)

˫

Temperature Resolution 0.1

˫

Temperature Basic error ±0.3

։

Current output 2 groups: 4 20mA
Signal output RS485 Modbus RTU
Other functions Data record &Curve display
Three relay control contacts 3 groups:5A 250VAC,5A 30VDC
Optional power supply 85~265VAC,9~36VDC,power consumption≤3W
Working conditions No strong magnetic field interference around except the geomagnetic field.

։ ˫

Working temperature -10 60
Relative humidity ≤90%
Waterproof rating IP65
Weight 0.8kg
Dimensions 144×144×118mm
Installation opening size 138×138mm
Installation methods Panel & wall mounted or pipeline

CS5560 Chlorine Dioxide Sensor

1

Model No.

CS5560

Measurement method

Tri-electrode method

Measure material

Double liquid junction,annular liquid junction

Housing material/Dimensions

PP, Glass, 120mm*Φ12.7mm

Waterproof grade

IP68

Measurement range

0 - 5.000 mg/L, 0 - 20.00 mg/L

Accuracy

±0.05mg/L;

Pressure resistance

≤0.3Mpa

Temperature compensation

None or Customize NTC10K

Temperature range

0-50℃

Calibration

Sample calibration

Connection methods

4 core cable

Cable length

Standard 5m cable, can be extended to 100m

Installation thread

PG13.5

Application

Tap water, disinfectant fluid, etc.

 