Gaining client pleasure is our company's aim without end. We are going to make excellent efforts to create new and top-quality goods, meet your special requirements and provide you with pre-sale, on-sale and after-sale companies for Liquified Natural Gas pH Electrode, Portable Turbidity Meter, Sensor Tds Arduino, We will wholeheartedly welcome all clients in the industry both at home and abroad to cooperate hand in hand, and create a bright future together.
Short Lead Time for Wireless Water Monitoring System - Online Turbidity Meter T6070 – Chunye Detail:

Turbidity
Function

The principle of the turbidity/sludge concentration sensor is based on the combined infrared absorption and scattered light method. The ISO7027 method can be used to continuously and accurately determine the turbidity or sludge concentration. According to ISO7027 infrared double- scattering light technology is not affected by chromaticity to determine the sludge concentration value. The self-cleaning function can be selected according to the use environment.

Stable data, reliable performance; built-in self-diagnosis function to ensure accurate data; simple installation and calibration.

Typical Use

The online turbidity meter is an online analytical instrument designed to measure the turbidity of water from waterworks, municipal pipeline network, industrial process water quality monitoring, circulating cooling water, activated carbon filter effluent, membrane filtration effluent, etc. especially in the treatment of municipal sewage or industrial wastewater.

Whether evaluating activated sludge and the entire biological treatment process, analyzing wastewater discharged after purification treatment, or detecting sludge concentration at different stages, the sludge concentration meter can give continuous and accurate measurement results.

Mains Supply

85~265VAC±10%,50±1Hz,power consumption ≤3W;
9~36VDC,power consumption:≤3W;

Measuring Range

Turbidity: 0~9999NTU

Features

1.Large display, standard 485 communication, with online and offline alarm, 144*144 meter size, 138*138 hole size, 4.3 inch large screen display.

2.The data curve recording function is installed, the machine replaces the manual meter reading, and the query range is arbitrarily specified, so that the data is no longer lost.

3.Real-time online recording of MLSS/SS, temperature data and curves, compatible with all water quality meters of our company.

4.0-20NTU, 0-400NTU, 0-4000NTU, a variety of measuring ranges are available, suitable for different working conditions, the measurement accuracy is less than ±5% of the measured value.

5.The new choke inductance of the power board can effectively reduce the influence of electromagnetic interference, and the data is more stable.

6.The design of the whole machine is waterproof and dustproof, and the back cover of the connection terminal is added to extend the service life in harsh environments.

7.Panel/wall/pipe installation, three options are available to meet various industrial site installation requirements.

Electrical connections

Electrical connection The connection between the instrument and the sensor: the power supply, output signal, relay alarm contact and the connection between the sensor and the instrument are all inside the instrument. The length of the lead wire for the fixed electrode is usually 5-10 meters, and the corresponding label or color on the sensor Insert the wire into the corresponding terminal inside the instrument and tighten it.

Instrument installation method

11

Technical specifications

Measurement range 0~9999NTU
Measurement unit NTU
Resolution 0.001NTU
Basic error ±1%F.S

˫

Temperature 0~50

˫

Temperature Resolution 0.1

˫

Temperature Basic error ±0.3
Current outputs Two 4~20mA,20~4mA,0~20mA
Signal output RS485 MODBUS RTU
Other functions Data record &Curve display
Three relay control contacts 5A 250VAC,5A 30VDC
Optional power supply 85~265VAC,9~36VDC,power consumption≤3W
Working conditions No strong magnetic field interference around except the geomagnetic field.

˫

Working temperature -10~60
Relative humidity ≤90%
Waterproof rating IP65
Weight 0.8kg
Dimensions 144×144×118mm
Installation opening size 138×138mm
Installation methods Panel & wall mounted or pipeline

Product detail pictures:

Short Lead Time for Wireless Water Monitoring System - Online Turbidity Meter T6070 – Chunye detail pictures

Short Lead Time for Wireless Water Monitoring System - Online Turbidity Meter T6070 – Chunye detail pictures

Short Lead Time for Wireless Water Monitoring System - Online Turbidity Meter T6070 – Chunye detail pictures


Related Product Guide:

It adheres to the tenet "Honest, industrious, enterprising, innovative" to develop new products constantly. It regards customers, success as its own success. Let us develop prosperous future hand in hand for Short Lead Time for Wireless Water Monitoring System - Online Turbidity Meter T6070 – Chunye , The product will supply to all over the world, such as: Egypt, Manila, Turkey, Now, with the development of internet, and the trend of internationalization, we've got decided to extend business to overseas market. With the propose of bringing more profits to oversea customers by providing directly abroad. So we have changed our mind, from home to abroad, hope to give our customers more profit, and looking forward to more chance to make business.
  • This is a reputable company, they have a high level of business management, good quality product and service, every cooperation is assured and delighted!
    5 Stars By Athena from Vancouver - 2017.09.09 10:18
    Problems can be quickly and effectively resolved, it is worth to be trust and working together.
    5 Stars By Cornelia from Seattle - 2017.02.14 13:19
    Write your message here and send it to us