Adhering into the theory of "quality, services, efficiency and growth", now we have gained trusts and praises from domestic and international shopper for Conductivity Electrode, Water Monitor System, Online Turbidimeter, Currently, we are looking forward to even greater cooperation with overseas customers based on mutual benefits. Please feel free to contact us for more details.
Top Quality Chemical Oxygen Demand COD Sensor RS485 - Online Residual Chlorine Meter T6550 – Chunye Detail:

Function

Online residual chlorine meter is a microprocessor-based water quality online monitoring control instrument.

Typical Use

This instrument is widely used in online monitoring of water supply, tap water, rural drinking water, circulating water, washing film water, disinfectant water, pool water. and other industrial processes. It continuous monitoring and control residual chlorine and  temperature  value  in aqueous solution.

Mains Supply

85~265VAC±10%,50±1Hz, power ≤3W;
9~36VDC, power consumption≤3W;

Measuring Range

Residual Chlorine: 0~20ppm; 0~20mg/L;
Temperature: 0~150℃.

Features

1.Large display, standard 485 communication, with online and offline alarm, 235*185*120mm meter size, 7.0 inch large screen display.

2.The data curve recording function is installed, the machine replaces the manual meter reading, and the query range is arbitrarily specified, so that the data is no longer lost.

3.Historical curve: The residual chlorine measurement data can be stored automatically every 5 minutes, and the residual chlorine value can be stored continuously for a month. Provide “history curve” display and “fixed point” query function on the same screen.

4.Built-in various measurement functions, one machine with multiple functions, meeting the requirements of various measurement standards.

5.The design of the whole machine is waterproof and dustproof, and the back cover of the connection terminal is added to extend the service life in harsh environments.

Electrical connections

Electrical connection The connection between the instrument and the sensor: the power supply, output signal, relay alarm contact and the connection between the sensor and the instrument are all inside the instrument. The length of the lead wire for the fixed electrode is usually 5-10 meters, and the corresponding label or color on the sensor Insert the wire into the corresponding terminal inside the instrument and tighten it.

Instrument installation method

bbb

Technical specifications

Measurement range 0.005~20.00mg/L ; 0.005~20.00ppm
Measurement unit Potentiometric method
Resolution 0.001mg/L ; 0.001ppm
Basic error ±1%F.S
Temperature -10 150.0 ˫( Based on sensor) 
Temperature Resolution 0.1˫
Temperature Basic error ±0.3˫
Current output 2 groups: 4 20mA
Signal output RS485 Modbus RTU
Other functions Data record &Curve display
Three relay control contacts 3 groups:5A 250VAC,5A 30VDC
Optional power supply 85~265VAC,9~36VDC,power consumption≤3W
Working conditions No strong magnetic field interference around except the geomagnetic field.
Working temperature -10 60
Working temperature 10։60˫
Relative humidity ≤90%
Waterproof rating IP65
Weight 1.5kg
Dimensions 235×185×120mm
Installation methods Wall mounted

1

Model No.

CS5530

Measurement method

Tri-electrode method

Measure material

Double liquid junction,annular liquid junction

Housing material/Dimensions

PP, Glass, 120mm*Φ12.7mm

Waterproof grade

IP68

Measurement range

0 – 5.000 mg/L, 0 – 20.00 mg/L

Accuracy

±0.05mg/L;

Pressure resistance

≤0.3Mpa

Temperature compensation

None or Customize NTC10K

Temperature range

0-50℃

Calibration

Sample calibration

Connection methods

4 core cable

Cable length

Standard 5m cable, can be extended to 100m

Installation thread

PG13.5

Application

Tap water, disinfectant fluid, etc.

 


Product detail pictures:

Top Quality Chemical Oxygen Demand COD Sensor RS485 - Online Residual Chlorine Meter T6550 – Chunye detail pictures

Top Quality Chemical Oxygen Demand COD Sensor RS485 - Online Residual Chlorine Meter T6550 – Chunye detail pictures

Top Quality Chemical Oxygen Demand COD Sensor RS485 - Online Residual Chlorine Meter T6550 – Chunye detail pictures


Related Product Guide:

Bear "Customer 1st, Good quality first" in mind, we work closely with our prospects and supply them with efficient and professional services for Top Quality Chemical Oxygen Demand COD Sensor RS485 - Online Residual Chlorine Meter T6550 – Chunye , The product will supply to all over the world, such as: Ukraine, Jordan, Qatar, Based on our automatic production line, steady material purchase channel and quick subcontract systems have been built in mainland China to meet customer's wider and higher requirement in recent years. We have been looking forward to cooperating with more clients worldwide for common development and mutual benefit!Your trust and approval are the best reward for our efforts. Keeping honest, innovative and efficient, we sincerely expect that we can be business partners to create our brilliant future!